<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-07 13-07-48
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 56 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 5.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 62 kHz 15876 7,9113
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,4 dBr 2,74 dBr 4,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 62 kHz MIN: 12 kHz % above 76 kHz: 7,9113 Acquired: 2024/08/07 13.06.45 Total samples: 15876 Equivalent time: 0:13:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 4,3 dBr MIN: 0,4 dBr AVE: 2,74 dBr % above 12,2 dBr: 0,0 Last value: 2,0 dBr (2024/08/07 13.06.45) 12.52 12.54 12.56 12.58 13.00 13.02 13.04 13.06 0 2 4 Pm [dBr]